> > > Pinpoint Nitrate Monitor w/probe
Pinpoint Nitrate Monitor w/probe | |
|  | Rating: none Quantity in Basket:
none Code: PIN-NM
Price:$239.95
|
|
| PINPOINT Nitrate Monitor
American Marine is proud to introduce the PINPOINT Nitrate Monitor. The
only truly affordable and accurate digital Nitrate measurement instrument
engineered for marine saltwater. The PINPOINT Nitrate Monitor has been
designed as a precision spot-testing instrument. There are 2 independent
measurement ranges: Low Range is 1–10 ppm nitrate and High Range is 10–100 ppm
nitrate. Resolution is 1 ppm in either scale. Accuracy is 1 ppm after
calibration. The PINPOINT Nitrate Monitor is sold complete with meter,
probe and all calibration fluids (9 volt battery not included).
Given proper care, the PINPOINT Nitrate Monitor™ should last a lifetime.
Powered by a standard 9-volt battery (not included).
Optional AC Adaptor Kit.
PINPOINT™ Nitrate Monitor
User's Guide
A 9-volt battery is recommended. Replace battery when "LOBAT"
appears on the display.
NOTE: The Nitrate Monitor unit is NOT waterproof and must be operated on
a dry surface. Liquid contact on the printed circuit board will cause
corrosion and void warranty.
Set-up
Unwrap the plastic protective packaging from both the meter and the probe.
Carefully unscrew and remove the plastic storage bottle from the end of the
probe. You may leave the bottle top on the probe. DO NOT discard the storage
bottle, it will be used for calibration, measurement and storage. Remove the
battery cover on the back of the monitor and install a 9-volt battery.
Attach the BNC connector to the input on the front of the monitor, and
rotate 1/4 turn clockwise to lock the connector.
High Range Calibration
- Pour 10 ppm Nitrate Calibration Fluid into the storage bottle to the
fill line. Insert the end of the probe into the fluid and screw the top
onto the bottle. Check the flat probe tip is not resting on the bottom of
the bottle.
- Slide the Range Switch to the HIGH position
- Press and release the ON/OFF button to power on the monitor.
- Press and release the Calibrate button. "CAL" will appear on the
display and the number 10 will flash slowly for about 40 seconds.
- When the number 100 starts to flash rapidly, the meter is ready for
the 100 ppm fluid. Donąt rush; you have as much time as you need. Unscrew
the bottle and return the 10 ppm calibration fluid back into its original
bottle. Pour 100 ppm nitrate calibration fluid into the storage bottle to
the fill line. Insert the end of the probe into the fluid and screw the
top onto the bottle. Check the flat probe tip is not resting on the bottom
of the bottle.
- Press and release the Calibrate button. The number 100 will flash
slowly for about 40 seconds. When the flashing stops the meter is fully
calibrated for the HIGH Range. Pour the 100 ppm calibration fluid back
into the original container.
- Pour a water sample to the fill line on the storage bottle and insert
the probe to determine the exact Nitrate level. Allow up to one minute for
the reading to stabilize. When finished, rinse the probe with R/O or
deionized water and blot dry with a paper towel prior to storage.
Low Range Calibration
- Pour 1 ppm Nitrate Calibration Fluid into the storage bottle to the
fill line. Insert the end of the probe into the fluid and screw the top
onto the bottle. Check the flat probe tip is not resting on the bottom of
the bottle.
- Slide the Range Switch to the LOW position
- Press and release the ON/OFF button to power on the monitor.
- Press and release the Calibrate button. "CAL" will appear on the
display and the number 1 will flash slowly for about 40 seconds.
- When the number 10 starts to flash rapidly, the meter is ready for the
10 ppm fluid. Don't rush; you have as much time as you need. Unscrew the
bottle and return the 1 ppm calibration fluid back into its original
bottle. Pour 10 ppm nitrate calibration fluid into the storage bottle to
the fill line. Insert the end of the probe into the fluid and screw the
top onto the bottle. Check the flat probe tip is not resting on the bottom
of the bottle.
- Press and release the Calibrate button. The number 10 will flash
slowly for about 40 seconds. When the flashing stops the meter is fully
calibrated for the LOW Range. Pour the 10 ppm calibration fluid back into
the original container.
- Pour a water sample to the fill line on the storage bottle and insert
the probe to determine the exact Nitrate level. Allow up to one minute for
the reading to stabilize. When finished, Rinse probe with RO or deionized
water and blot dry with a paper towel prior to storage.
Important Points to Remember
- PINPOINT Nitrate Monitor has been designed as a
precision spot testing monitor. Continuous Nitrate Monitoring may not be
possible in most situations and may require frequent recalibration and
probe replacement.
- PINPOINT Nitrate Monitor is NOT waterproof and must be
operated on a dry surface. Liquid contact with the printed circuit board
may cause corrosion and void warranty.
- PINPOINT Nitrate Monitor has 2 independent ranges:
0 – 10 ppm NO3
10–100 ppm NO3
Accuracy for either scale after calibration is +/- 1 ppm NO3
Resolution for either scale is 1 ppm NO3
- When the probe is not in use, the tip should be stored in the
protective bottle-dry. That is with NO fluid added to the bottle. A
properly stored probe may have a life of up to 2-3 years.
- For greatest accuracy all calibration and sample fluids should be at
(the same) room temperature.
- Calibration is recommended before each measurement.
- PINPOINT Nitrate Probe should be kept very clean.
Rinse off the probe tip with RO/DI water and blot with a paper towel to
dry prior to storage. Do not use any cleaning fluids or chemicals.
- Calibration fluids can be reused and should be replaced occasionally.
Calibration Fluid replacement will depend on individual technique and be
indicated by the inability to calibrate.
- For increased stability allow the probe tip to soak in calibration
fluid 5 minutes before initial calibration.
ErŠP on the display indicates a probe malfunction. Check to see that the
BNC is properly attached to the meter input.
- Lo on the display indicates the probe is measuring a nitrate value
below the selected scale.
- High on the display indicates the probe is measuring a nitrate value
above the selected scale.
Warranty
PINPOINT™ Nitrate Monitor
by American Marine Inc. is warranted to be free of defects in material and
workmanship for a period of 2 years from date of sale.
PINPOINT™ Nitrate Probe
is warranted to be free of defects in material and workmanship for a period
of 6 months from the date of sale.
Positive proof of purchase is required for warranty claim.
American Marine Inc. will not be liable for any costs of removal,
installation, transportation charges, or any other charges, which may result
in connection with a warranty claim.
American Marine Inc. will not be liable for any damage or wear to products
or livestock caused by abnormal operating conditions, water damage, abuse,
misuse, unauthorized alternation or repair or if the product was not
installed in accordance with the printed operating instructions. Any
defective product must be sent freight prepaid with appropriate
documentation supporting the warranty claim. Replacement or repair will be
at the discretion of American Marine Inc.
American Marine Inc.
54 Danbury Road, Suite 172
Ridgefield, CT 06877 U.S.A.
Fax/Phone: 914-763-5367
|
|
Customer Reviews
No reviews added yet. Add Your Review
| |